1.
Chinese Journal of Medical Instrumentation ; (6): 377-382, 2023.
Article in Chinese | WPRIM | ID: wpr-982249

ABSTRACT

Dynamic multi-leaf collimator, which has the function of radiation beam shaping, is a key executive component of tumor precise radiotherapy, and plays a core role in improving the accuracy, efficiency and quality of radiotherapy. A new type of collimator leaf end structure with circular arc and plane combination was studied, and collimator penumbra performance analysis model combining analytical expression and graphic analysis was developed. The influence of leaf end structure on penumbra was analyzed quantitatively, and a set of three-dimensional structure design of dynamic multi-leaf collimator was completed. The feasibility of the structural design and analysis model was verified through experimental measurements.


Subject(s)
Humans , Radiotherapy Planning, Computer-Assisted/methods , Particle Accelerators , Neoplasms , Radiotherapy Dosage
2.
Chinese Journal of Medical Instrumentation ; (6): 365-369, 2023.
Article in Chinese | WPRIM | ID: wpr-982247

ABSTRACT

OBJECTIVE@#To study the feasibility and potential benefits of beam angle optimization (BAO) to automated planning in liver cancer.@*METHODS@#An approach of beam angle sampling is proposed to implement BAO along with the module Auto-planning in treatment planning system (TPS) Pinnacle. An in-house developed plan quality metric (PQM) is taken as the preferred evaluating method during the sampling. The process is driven automatically by in-house made Pinnacle scripts both in sampling and scoring. In addition, dosimetry analysis and physician's opinion are also performed as the supplementary and compared with the result of PQM.@*RESULTS@#It is revealed by the numerical analysis of PQM scores that only 15% patients whose superior trials evaluated by PQM are also the initial trials. Gantry optimization can bring benefit to plan quality along with auto-planning in liver cancer. Similar results are provided by both dose comparison and physician's opinion.@*CONCLUSIONS@#It is possible to introduce a full automated approach of beam angle optimization to automated planning process. The advantages of this procedure can be observed both in numerical analysis and physician's opinion.


Subject(s)
Humans , Radiotherapy Planning, Computer-Assisted/methods , Feasibility Studies , Radiometry/methods , Liver Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage
3.
Chinese Journal of Medical Instrumentation ; (6): 360-364, 2023.
Article in Chinese | WPRIM | ID: wpr-982246

ABSTRACT

Advanced radiotherapy technology enables the dose to more accurately conform to the tumor target area of the patient, providing accurate treatment for the patient, but the gradient of the patient's radiation dose at the tumor edge is getting larger, which putting forward higher requirements for radiotherapy dose verification. The dose verification system software KylinRay-Dose4D can verify the patient's pre-treatment plan and the in vivo/on-line dose during the patient's treatment, providing important reference for the physicist to modify the radiotherapy plan and ensuring that the patient receives accurate treatment. This study introduces the overall design and key technologies of KylinRay-Dose4D, and tests the pre-treatment plan dose checking calculation and 2D/3D dose verification through clinical cases. The test results showed that the 2D/3D gamma pass rate (3 mm/3%) of KylinRay-Dose4D reconstructed dose compared with TPS plan dose and measured dose is larger than 95%, which indicating that the reconstructed dose of KylinRay-Dose4D meets the requirement of clinical application.


Subject(s)
Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Software , Neoplasms , Phantoms, Imaging , Radiometry/methods
4.
Chinese Journal of Medical Instrumentation ; (6): 355-359, 2023.
Article in Chinese | WPRIM | ID: wpr-982245

ABSTRACT

In recent years, proton therapy technology has developed rapidly, and the number of patients treated with proton therapy has gradually increased. However, the application of proton therapy technology was far from practical needs. Because of the shortage of resources and the high cost, proton therapy systems are not accessible and affordable for most patients. In order to change this situation, it is necessary to develop a new truly practical proton therapy system based on clinical needs. Conceptual design of a practical proton therapy system was proposed. Compared with the existing system, one feature of the newly designed system is to reduce the maximum energy of the proton beam to 175~200 MeV; another feature is the configuration of deluxe and economical treatment rooms, the deluxe room is equipped with a rotating gantry and a six-dimensional treatment bed, and the economical room is equipped with a horizontal fixed beam and a patient vertical rotating setup device. This design can not only reduce the cost of proton therapy system and equipment room construction, but also facilitate the hospital to choose the appropriate configuration, which will ultimately benefit more patients.


Subject(s)
Humans , Proton Therapy , Radiotherapy Planning, Computer-Assisted , Hospitals , Radiotherapy Dosage
5.
Chinese Journal of Medical Instrumentation ; (6): 237-241, 2023.
Article in Chinese | WPRIM | ID: wpr-982220

ABSTRACT

Biology-guided radiotherapy (BgRT) is a novel technique of external beam radiotherapy, combining positron emission tomography-computed tomography (PET-CT) with a linear accelerator (LINAC). The key innovation is to utilize PET signals from tracers in tumor tissues for real-time tracking and guiding beamlets. Compared with a traditional LINAC system, a BgRT system is more complex in hardware design, software algorithm, system integration and clinical workflow. RefleXion Medical has developed the world's first BgRT system. Nevertheless, its actively advertised function, PET-guided radiotherapy, is still in the research and development phase. In this review study, we presented a number of issues related to BgRT, including its technical advantages and potential challenges.


Subject(s)
Positron Emission Tomography Computed Tomography , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Particle Accelerators , Biology , Radiotherapy, Image-Guided/methods , Radiotherapy Dosage
6.
Chinese Journal of Medical Instrumentation ; (6): 110-114, 2023.
Article in Chinese | WPRIM | ID: wpr-971314

ABSTRACT

The purpose of this study is to establish and apply a correction method for titanium alloy implant in spinal IMRT plan, a corrected CT-density table was revised from normal CT-density table to include the density of titanium alloy implant. Dose distribution after and before correction were calculated and compared to evaluate the dose deviation. Plans were also copied to a spinal cancer simulation phantom. A titanium alloy fixation system for spine was implanted in this phantom. Plans were recalculated and compared with the measurement result. The result of this study shows that the max dose of spinal cord showed significant difference after correction, and the deviation between calculation results and measurement results was reduced after correction. The method for expanding the range CT-density table, which means that the density of titanium alloy was included, can reduce the error in calculation.


Subject(s)
Radiotherapy, Intensity-Modulated/methods , Titanium , Radiotherapy Dosage , Alloys , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods
7.
J. health med. sci. (Print) ; 8(1): 45-50, ene.-mar. 2022. ilus, graf, tab
Article in English | LILACS | ID: biblio-1395758

ABSTRACT

Radiation absorbed doses to organs outside the radiation therapy treatment beam can be significant and therefore of clinical interest. Two sets of out-of-beam measurements were performed measuring the leak dose and the scattered dose, at 5 points within the accelerator components (accelerator tube and collimator) and at 21 points on the equipment and surroundings based on a positioning scheme. For this purpose, 52 Optically Stimulated Luminescence (OSL) dosimeters were used in a latest generation helical linear accelerator. Of the 200 cGy fired at a cheese-like phantom, 0.332% of the out-of-beam dose contribution was found to come from the leak and 0.784% was transformed into scattering. For these dose values, estimates of the risk of second tumors in long-term survivors indicate a reduced probability of acquiring a second secondary radiation malignancy, based on information from the 1990 BEIR Committee report.


La dosis absorbida de radiación a órganos fuera del haz de tratamiento de radioterapia puede ser significativa y, por lo tanto, de interés clínico. Se realizaron dos sets de mediciones fuera del haz para determinar la dosis de fuga y la dosis dispersa, en 5 puntos dentro de los componentes del acelerador (tubo de aceleración y colimador) y 21 puntos en el equipo y alrededores basado en un esquema de posicionamiento. Para este fin se utilizaron 52 dosímetros de luminiscencia estimulada ópticamente (OSL, Optically Stimulated Luminescence), en un acelerador lineal helicoidal de última generación. De los 200 cGy disparados a un maniquí tipo queso, se encontró que el 0.332% de la contribución de dosis fuera del haz provenía de la fuga y 0.784% se transforma en dispersión. Para estos valores de dosis, las estimaciones del riesgo de segundos tumores en los supervivientes a largo plazo indican una reducida probabilidad de contraer una segunda malignidad por radiación secundaria, según la información del informe del Comité BEIR de 1990.


Subject(s)
Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Optically Stimulated Luminescence Dosimetry , Radiometry/instrumentation , Thermoluminescent Dosimetry , Calibration , Luminescence , Luminescent Measurements
8.
Journal of Southern Medical University ; (12): 1089-1094, 2022.
Article in Chinese | WPRIM | ID: wpr-941046

ABSTRACT

OBJECTIVE@#To investigate the influence of positioning accuracy of the multi-leaf collimators (MLC) on the passing rate of the plan dose verification for volumetric modulation arc therapy (VMAT) of cervical cancer using an Elekta linear accelerator.@*METHODS@#The dose distributions were measured using Sun Nuclear's Mapcheck and Arccheck semiconductors matrix before and after MLC calibration in30 cervical cancer patients undergoing VMAT. Dosimetric comparisons were performed with 2D and 3D gamma passing rates of 3%, 3 mm and 2%, and 2 mm. The 3D gamma distribution was reconstructed with respect to the patient's anatomy using 3DVH software to evaluate the possible influence of MLC positioning accuracy.@*RESULTS@#Before and after MLC calibration, the gamma passing rates of Mapcheck were (88.80±1.81)% and (99.25 ± 0.53)% under 3% and 3 mm standard, respectively, with an average increase of 10.45%. The corresponding gamma passing rates of Arccheck were (87.61±1.98)% and (98.13±0.99)%, respectively, with an average increase of 10.52%. The gamma passing rates of 3DVH were (89.87±2.28)% and (98.3±1.15)%, respectively, with an average increase of 8.43%.@*CONCLUSION@#The MLC positioning accuracy is one of the main factors influencing dosimetric accuracy of VMAT for cervical cancer. The application of Autocal software facilitates MLC calibration and improves the accuracy and safety of VMAT delivery for cervical cancer.


Subject(s)
Female , Humans , Particle Accelerators , Quality Control , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Uterine Cervical Neoplasms/radiotherapy
9.
Chinese Journal of Contemporary Pediatrics ; (12): 631-634, 2022.
Article in Chinese | WPRIM | ID: wpr-939640

ABSTRACT

OBJECTIVES@#To study the clinical application effect of "kindergarten effect" in radiotherapy for children with tumor based on the psychology of preschool children aged 3-5 years.@*METHODS@#A total of 30 children, aged 3-5 years, who were admitted to the Department of Radiotherapy, Tianjin Medical University Cancer Institute and Hospital, from January 2020 to August 2021 were enrolled in this prospective study. The children were randomly divided into a control group and a test group, with 15 children in each group. The children in the test group were treated in "kindergarten mode", i.e., all children were treated together at a specified time and left together after all children completed treatment. Those in the control group were treated alternately with adult patients according to the treatment time based on the type of radiotherapy fixation device. The treatment compliance was evaluated for both groups, and the two groups were compared in terms of the setup errors in the superior-inferior (SI), left-right (LR), and anterior-posterior (AP) directions.@*RESULTS@#Compared with the control group, the test group showed a significantly shorter time for finishing the treatment (P<0.05) and a significantly lower proportion of children with treatment interruption (P<0.05). Compared with the control group, the test group showed smaller mean errors in the SI, LR and AP directions after image-guided radiotherapy, with significant differences in the mean errors in the SI and LR directions (P<0.05).@*CONCLUSIONS@#With the application of the "kindergarten effect", most children can actively cooperate in radiotherapy, and it can also improve the accuracy and repeatability of positioning and help to achieve the desired treatment outcome.


Subject(s)
Adult , Humans , Neoplasms/radiotherapy , Prospective Studies , Radiotherapy Planning, Computer-Assisted
10.
Chinese Journal of Medical Instrumentation ; (6): 108-113, 2022.
Article in Chinese | WPRIM | ID: wpr-928869

ABSTRACT

To study an automatic plan(AP) method for radiotherapy after breast-conserving surgery based on TiGRT system and and compare with manual plan (MP). The dosimetry parameters of 10 patients and the evaluation of scoring table were analyzed, it was found that the targets dose of AP were better than that of MP, but there was no statistical difference except for CI, The V5, V20 and V30 of affected lungs and whole lungs in AP were lower than all that in MP, the Dmean of hearts was slightly higher than that of MP, but the difference was not statistically significant, the MU of AP was increase by 16.1% compared with MP, the score of AP evaluation was increase by 6.1% compared with MP. So the AP could be programmed and automated while ensuring the quality of the plan, and can be used to design the plans for radiotherapy after breast-conserving surgery.


Subject(s)
Female , Humans , Breast Neoplasms/surgery , Mastectomy, Segmental , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated
11.
Journal of Peking University(Health Sciences) ; (6): 182-186, 2022.
Article in Chinese | WPRIM | ID: wpr-936132

ABSTRACT

OBJECTIVE@#To assess the potential dosimetric effects of arms movement in patients with Cyberknife spine tumors.@*METHODS@#In the study, 12 patients with thoracic and lumbar tumors were retrospectively selected respectively. The contour of the patient's arms was sketched and the CT density was modified to be equivalent to air in order to simulate the extreme case when the arm was completely removed from the radiation fields. The dose of simulated plan was re-calculated with the original beam parameters and compared with the original plan. The changes of V100, D95, and D90, conformity index (CI) and heterogeneity index (HI) in planning target volume (PTV), as well as Dmax, D1cc and D2cc in the spinal cord, stomach, esophagus, and intestines were analyzed by comparing with the original plans.@*RESULTS@#Compared with the original treatment plan, V100, D95, D90 and CI of PTV for the simulated plan was increased by 0.86%, 2.02%, 1.97% and 0.80% respectively, the difference was statistically significant (P < 0.05). Dmax, D1cc and D2cc of spinal cord was increased by 2.35%, 0.59% and 1.49% on average, compared with the original plan, the difference was statistically significant (P < 0.05). The difference was statistically significant only in average D2cc of stomach, which was increased by 1.70%, compared with the original plan (P < 0.05). There was no significant difference in dose change of eso-phagus and intestine between the original and simulated plans.@*CONCLUSION@#This study analyzed the most extreme arm position in spinal tumor of radiation therapy based on Cyberknife. It was found that the change of arm position had little effect on dosimetry. In addition, with the change of arm position, the dose in PTV and organ at risk (OAR) increased, but the increase was relatively small. Therefore, in some special cases where the patient really can't keep the arm position consistent during treatment, reasonable adjustment can be accepted. However, in order to ensure accurate radiotherapy, patient position should be as stable and consistent as possible.


Subject(s)
Humans , Arm , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Retrospective Studies , Spinal Neoplasms/surgery
12.
Rev. Assoc. Med. Bras. (1992) ; 67(8): 1118-1123, Aug. 2021. tab
Article in English | LILACS | ID: biblio-1346969

ABSTRACT

SUMMARY OBJECTIVE: The aim of this study was to perform dosimetric analysis of radiotherapy (RT) plans with or without elective nodal irradiation (ENI) and estimate whether the increase in mean doses (MDs) in the heart and lungs with ENI may lead to late side effects that may surpass the benefits of treatment. METHODS: The dosimetric analysis of 30 treatment plans was done with or without ENI. The planning and dose-volume histograms were analyzed, and the impact on the mortality of cardiovascular and lung cancer was estimated based on the correlation of the dosimetric data with data from population studies. RESULTS: RT with ENI increased the doses in the lungs and heterogeneity in the plans compared to breast-exclusive RT. When the increase in MDs is correlated with the increase of late side-effect risks, the most important effect of ENI is the increased risk of lung cancer, especially in patients who smoke (average increase in absolute risk=1.38%). The increase in the absolute risk of cardiovascular diseases was below 0.1% in the all the situations analyzed. CONCLUSIONS: ENI increases the heterogeneity and the doses at the lungs. When recommending ENI, the risks and benefits must be taken into account, considering the oncology factors and the plan of each patient. Special attention must be given to patients who smoke as ENI may lead to a significant increase in MD in the lung and the increased risk of radiation-induced lung cancer may surpass the benefits from this treatment.


Subject(s)
Humans , Female , Breast Neoplasms/radiotherapy , Cardiovascular Diseases/etiology , Neoplasms, Second Primary , Carcinoma, Non-Small-Cell Lung , Radiotherapy, Conformal , Lung Neoplasms/etiology , Lung Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted , Risk Factors , Heart Disease Risk Factors , Lymph Nodes
14.
Chinese Journal of Medical Instrumentation ; (6): 454-458, 2021.
Article in Chinese | WPRIM | ID: wpr-888645

ABSTRACT

Dose verification is carried out on the individualized three-dimensional phantom based on 3D printing technology, which simulates the anatomical structure of human body, contour shape, tumor anatomical structure and other dangerous organs to the greatest extent, and produces a reasonable and effective dose validation phantom. According to the need to obtain effective patient data, import Mimics software to reconstruct the parts of the body and its surrounding tissues and organs that need to be measured, and make them into three-dimensional shell components. The 3D printing is used to assemble and fill the equivalent tissue, and then the body phantom is made. The phantom was scanned by CT and the data was transmitted to TPS system. The previously completed treatment plan was transplanted to the phantom. The phantom was placed according to the patient's location information, irradiated and measured data. The three-dimensional shell assembly is completely reconstructed according to the patient's data, and the contour difference is not significant. The shell is filled with tissue radiation equivalent material whose CT value is the same as the average CT value of the shell volume. The CT image data show that the radiation equivalence of the phantom is similar to the actual tissue of the patient, and the equivalent dose distribution conforms to the conventional treatment range. It can provide a reliable means of dose verification for the accurate design of intensity modulated radiation therapy.


Subject(s)
Humans , Phantoms, Imaging , Printing, Three-Dimensional , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated
15.
Chinese Journal of Medical Instrumentation ; (6): 573-579, 2021.
Article in Chinese | WPRIM | ID: wpr-922062

ABSTRACT

OBJECTIVE@#To explore the feasibility of using the bidirectional local distance based medical similarity index (MSI) to evaluate automatic segmentation on medical images.@*METHODS@#Taking the intermediate risk clinical target volume for nasopharyngeal carcinoma manually segmented by an experience radiation oncologist as region of interest, using Atlas-based and deep-learning-based methods to obtain automatic segmentation respectively, and calculated multiple MSI and Dice similarity coefficient (DSC) between manual segmentation and automatic segmentation. Then the difference between MSI and DSC was comparatively analyzed.@*RESULTS@#DSC values for Atlas-based and deep-learning-based automatic segmentation were 0.73 and 0.84 respectively. MSI values for them varied between 0.29~0.78 and 0.44~0.91 under different inside-outside-level.@*CONCLUSIONS@#It is feasible to use MSI to evaluate the results of automatic segmentation. By setting the penalty coefficient, it can reflect phenomena such as under-delineation and over-delineation, and improve the sensitivity of medical image contour similarity evaluation.


Subject(s)
Feasibility Studies , Radiotherapy Planning, Computer-Assisted
16.
Journal of Central South University(Medical Sciences) ; (12): 475-480, 2021.
Article in English | WPRIM | ID: wpr-880684

ABSTRACT

OBJECTIVES@#To study the feasibility of ArcCHECK-3DVH system in dosimetric verification for stereotactic body radiaotherapy (SBRT) with flattening filter free (FFF) model.@*METHODS@#SBRT treatment plans for 57 patients were introduced into ArcCHECK phantom and recalculated. The calculated dose distribution of treatment planning system and the measured dose distribution of ArcCHECK phantom were compared by γ analysis. Then the 3 dimensional dose distribution of target and organs at risk was reconstructed by 3DVH software. The reconstructed dose and calculated dose with treatment planning system (TPS) were compared, and the dose volume γ pass rate and deviation of dose volume parameters to the target and organs at risk were quantitatively valuated.@*RESULTS@#Based on the threshold criteria (3%, 3 mm, 10%), namely the deviation of measuring points between the planned value and the measured value was less than 3%, and the proportion of points with similar values in the plane or sphere with the center of the point and the radius of 3 mm was 10%, the relative and absolute dose pass rates of SBRT treatment plans in ArcCHECK system via γ analysis were greater than 95%. Based on the stricter threshold criteria (2%, 2 mm, 10%), the relative and absolute dose pass rates of SBRT treatment plan in ArcCHECK system via γ analysis were about 93%. In 3DVH dose verification, the γ pass rate of target and organs at risk was exceed 97%, and the deviations in 3DVH of the target and organs at risk were less than ±5%.@*CONCLUSIONS@#The ArcCHECK-3DVH system in dose verification can provide more comprehensive dose distribution information to reasonably evaluate the SBRT plan, with more significance for guiding clinical treatment.


Subject(s)
Humans , Phantoms, Imaging , Quality Assurance, Health Care , Radiometry , Radiosurgery , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated
17.
Chinese Journal of Medical Instrumentation ; (6): 231-236, 2021.
Article in Chinese | WPRIM | ID: wpr-880458

ABSTRACT

Accurate CT simulation is the key link of precision radiotherapy, and the performance of the localization couch of CT simulator directly affects the accuracy of radiotherapy. With the rapid development of precision radiotherapy, conventional large aperture radiotherapy special CT simulator is difficult to meet the needs of precision radiotherapy localization, so most radiotherapy centers choose high-end diagnostic CT machines equipped with a flat tabletop for radiotherapy localization. In clinical work, the performance testing of the CT simulator localization couch is easy to be ignored. In addition, there are some problems such as insufficient precision in transforming the cradle-shaped couch top of diagnostic CT into a special flat couch top for radiotherapy. This paper provided an in-depth description of the improved design and performance test of the localization couch of the first special GE Revolution CT simulator for radiotherapy introduced by West China Hospital of Sichuan University. After the improvement, all the acceptance tests of the localization couch are in line with the standard, and the performance meets the high-precision radiotherapy localization needs of patients with different body weight in the center.


Subject(s)
Humans , China , Computer Simulation , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted , Tomography, X-Ray Computed
18.
Chinese Journal of Medical Instrumentation ; (6): 163-166, 2021.
Article in Chinese | WPRIM | ID: wpr-880444

ABSTRACT

In order to adapt to different target shapes and protect the surrounding normal tissues, the design of two-dimensional electron beam radiotherapy planning requires additional lead blocks. But the Pinnacle treatment planning system can not directly shape the lead block conformity to the size of the beam field given by the doctor. Every time, physicists need to manually drag the lead block to form the required beam field. When meeting a two-dimensional electron beam treatment planning with the same field parameters as before, physicists need to rearrange the field for dose calculation, which greatly reduces the design efficiency of the two-dimensional electron beam treatment planning. In this study, we independently developed a two-dimensional electron beam radiotherapy planning system based on Qt Creator. The system can quickly design a two-dimensional electron beam radiotherapy plan, which reduces the repeated work of physicists.


Subject(s)
Electrons , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
19.
Chinese Journal of Medical Instrumentation ; (6): 109-113, 2021.
Article in Chinese | WPRIM | ID: wpr-880434

ABSTRACT

Clinically, beam matching can greatly improve the flexibility and efficiency of treating patients between different medical electron linacs. However, in addition to the regular quality assurance (QA) test of the machine performance of linacs, there is still a lack of comprehensive evaluation of the clinical radiotherapy performance of beam-matched linacs. In this paper, the performance of volumetric modulated arc therapy (VMAT) between three closely matched linacs was evaluated by statistical process control (SPC) technology. It was found that the average and median γ passing rates of the VMAT QA processes of the three linacs had little difference, but the process capability levels were at three different levels. The results show that SPC technology can effectively evaluate the performance of beam matching for medical electron linacs, improve the patient-specific VMAT QA processes, and guide clinical decision-making.


Subject(s)
Electrons , Particle Accelerators , Quality Assurance, Health Care , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated
20.
Journal of Biomedical Engineering ; (6): 161-168, 2021.
Article in Chinese | WPRIM | ID: wpr-879262

ABSTRACT

Image-guided radiation therapy using magnetic resonance imaging (MRI) is a new technology that has been widely studied and developed in recent years. The technology combines the advantages of MRI imaging, and can offer online real-time tracking of tumor and adjacent organs at risk, as well as real-time optimization of radiotherapy plan. In order to provide a comprehensive understanding of this technology, and to grasp the international development and trends in this field, this paper reviews and summarizes related researches, so as to make the researchers and clinical personnel in this field to understand recent status of this technology, and carry out corresponding researches. This paper summarizes the advantages of MRI and the research progress of MRI linear accelerator (MR-Linac), online guidance, adaptive optimization, and dosimetry-related research. Possible development direction of these technologies in the future is also discussed. It is expected that this review can provide a certain reference value for clinician and related researchers to understand the research progress in the field.


Subject(s)
Magnetic Resonance Imaging , Particle Accelerators , Radiometry , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Image-Guided